Patient Monitor with VGA and touch screen
2017-08-23 01:12  Visit:100
Price:Unfilled
Send inquiry
Basic Info
  • Model NO.: PM-70

  • Type: Patient/Fetal/Maternal Monitor

  • Trademark: Contec

  • Origin: China

  • Classification: Physiological Functions of Diagnosis and Monitoring Equipment

  • Parameters: ECG, SpO2, NIBP Pulse Rate

  • Specification: ECG, SpO2, NIBP Pulse Rate

  • HS Code: 90181930

Product Description
Introduction
PM70 Patient Monitorcan be used for all-round monitoring for adult, pediatric and neonatal for ECG, NIBP and SpO2, etc.
Features
All-round monitoring for adult, pediatric and neonatal.
3.5'' (320× 240) TFT LCD.
Operate with button and touch screen.
Review of data list and trend graph.
Configuring interface as user's requirements.
Audible and visual alarm for each parameter, and upper and lower limit of alarm can be set.
Built-in rechargeable Li-polymer battery for uninterrupted monitoring.
Performance
ECG
3-lead and 5-lead are optional.
Waveform display: Dual-lead/full-lead
Gain selection: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV
Measurement range for Heart rate(HR): 30bpm~300bpm, error: ± 1bpm or ± 1%, whichever is greater.
Upper and lower limit for alarm range: 30bpm~300bpm, resolution: 1bpm
Input current: ≤ 0.1μ A
Enduring polarization voltage: ± 300mV, sensitivity range: ± 5%.
CMRR: Filter mode(surgery, monitoring)≥ 80dB
Frequency response: 1~75Hz(+0.4dB, -3dB)
Low-frequency characteristic: Time constant≥ 3.2s
Analysis function: Heart rate, arrhythmia analysis, S-T segment analysis
S-T segment range: -2.0mV~2.0mV
Blood Pressure
Measurement method: Oscillometry
Measurement mode: Manual/auto/continuous.
Auto measurement interval: Adjustable from 1 to 90 minutes.
Resolution: 1mmHg.
Accuracy: Maximum Mean deviation≤ ± 5mmHg, Maximum Standard deviation≤ 8mmHg.
Self-check function.
Overpressure protection: Double protection for software and hardware.
1) Range
Adult:
Systolic pressure: 40mmHg~270mmHg
Mean pressure: 20mmHg~235mmHg
Diastolic Pressure: 10mmHg~215mmHg

Pediatric:
Systolic pressure: 40mmHg~200mmHg
Mean pressure: 20mmHg~165mmHg
Diastolic Pressure: 10mmHg~150mmHg
Neonatal:
Systolic pressure: 40mmHg~135mmHg
Mean pressure: 20mmHg~110mmHg
Diastolic Pressure: 10mmHg~100mmHg

2) Upper and lower limit of alarm
Adult:
Systolic pressure: 40mmHg~270mmHg
Mean pressure: 20mmHg~235mmHg
Diastolic Pressure: 10mmHg~215mmHg

Pediatric:
Systolic pressure: 40mmHg~200mmHg
Mean pressure: 20mmHg~165mmHg
Diastolic Pressure: 10mmHg~150mmHg

Neonatal:
Systolic pressure: 40mmHg~135mmHg
Mean pressure: 20mmHg~110mmHg
Diastolic Pressure: 10mmHg~100mmHg
SpO2 monitoring
Continuous real-time measuring.
Adopt digital SpO2 technology, which has strong anti-interference capability.
Real-time display SpO2, Pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.
Trend graph with the function of adaptive scaling
Standard finger-clip probe for adult, binding probe for neonatal is optional.
1) SpO2
MeasuringRange: 35%~100% (Resolution: 1%)
Accuracy: ± 2% in stage of 70%-100%, and unspecified in stage of less than 70%.
2) Pulse Rate
MeasuringRange: 30bpm~250bpm(Resolution: 1bpm)
Accuracy: ± 2bpm or ± 2%, whichever is greater.
3) Measurement Performance in Weak Filling Condition: SpO2 and Pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ± 4%; The Pulse rate error is ± 2bpm or ± 2%, whichever is greater. 4) Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%.
Accessories
A power adapter
An ECG lead wire
A SpO2 probe
An adult NIBP cuff
A base of the PM70
Performance  Specifications  
Display:   3.5"   Color  TFT
Resolution:   320x240
Display  Mode:   Standard  face,   Waveform  face
Indicator:   Power  indicator  light,   Alarm  sound,   Pluse  tone
Interface:   Socket  for  connecting  sensors  and  sockets  for  communication  cables
Power  Supply:   DC  5V,   < 300mA
Battery: Builtin  Li-Polymer,   2  hours  for  charging,   3  hours  for  continous  working.   8  hours  for  standby  mode
Trend  Graph:   Resolution  from  1s,   5s,   10s.   Maximum  time  96  hours.
Trend  Table:   Resolution  from  1s,   5s,   10s.   Review  up  to  1000  items.
Alarm:   Ajustable  High  and  Low  limits.   Three  level  audible  and  vistual  alarm
User  Configuration:   All  the  color  of  parameters  and  waves  can  be  set  according  to  user' s  willing
   
Technical  specifications:  
Safety Meet  the  requirment  of  IEC60601  series
Type  of  Protection: Class  II  with  internal  electirc  power  supply
Degree  of  Protection: BF
   
Dimention  and  Weight  
Dimention:   145(W)x95(H)x37(D)mm
Weight:   400g(with  battery)
   
Operation  Environment: Temperature:   0~  +40
  Humidity:   15%  ~  95%
Storage  Environment: Temperature:   -20~  +60
  Humidity:   10%  ~  95%
Patient  Range Neonate,   Pediatric  and  Adult
   
SpO2:  
Measurement  Range:   0  ~  100%
Resolution:   1%
Accuracy:   &#177;   2%(70%~100%,   Adult/Pediatric,   non-motion)
  &#177;   3%(70%~100%,   Neonate,   non-motion)
  0%  ~  69%  unspecified
Alarm  Range:   0%  ~  100%
Refreshing  Rate:   1s
   
Pulse  Rate:  
Measurement  Range:   25  ~  250  bpm
Resolution: 1bpm
Accuracy:   &#177;   3  bpm  (non-motion)
Alarm  Range:   25  ~  250  BMP
Refreshing  Rate: 1s
   
NIBP:  
Method:   Oscillometry
Mode:   Manual/Auto/Contiuous
Measurement  Range:   25  ~  260mmHg
Atuo  Measure  Interval: 5,   10,   15,   30,   45,   60,   90  Minutes
Resolution:   1mmHg
Overpressure  Protection:   300mmHg
Alarm  range: 25  ~260mmHg
 