Send inquiry
Basic Info
Model NO.: PM-70
Type: Patient/Fetal/Maternal Monitor
Trademark: Contec
Origin: China
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Parameters: ECG, SpO2, NIBP Pulse Rate
Specification: ECG, SpO2, NIBP Pulse Rate
HS Code: 90181930
Product Description
Introduction
PM70 Patient Monitorcan be used for all-round monitoring for adult, pediatric and neonatal for ECG, NIBP and SpO2, etc.
Features
All-round monitoring for adult, pediatric and neonatal.
3.5'' (320× 240) TFT LCD.
Operate with button and touch screen.
Review of data list and trend graph.
Configuring interface as user's requirements.
Audible and visual alarm for each parameter, and upper and lower limit of alarm can be set.
Built-in rechargeable Li-polymer battery for uninterrupted monitoring.
Performance
ECG
3-lead and 5-lead are optional.
Waveform display: Dual-lead/full-lead
Gain selection: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV
Measurement range for Heart rate(HR): 30bpm~300bpm, error: ± 1bpm or ± 1%, whichever is greater.
Upper and lower limit for alarm range: 30bpm~300bpm, resolution: 1bpm
Input current: ≤ 0.1μ A
Enduring polarization voltage: ± 300mV, sensitivity range: ± 5%.
CMRR: Filter mode(surgery, monitoring)≥ 80dB
Frequency response: 1~75Hz(+0.4dB, -3dB)
Low-frequency characteristic: Time constant≥ 3.2s
Analysis function: Heart rate, arrhythmia analysis, S-T segment analysis
S-T segment range: -2.0mV~2.0mV
Blood Pressure
Measurement method: Oscillometry
Measurement mode: Manual/auto/continuous.
Auto measurement interval: Adjustable from 1 to 90 minutes.
Resolution: 1mmHg.
Accuracy: Maximum Mean deviation≤ ± 5mmHg, Maximum Standard deviation≤ 8mmHg.
Self-check function.
Overpressure protection: Double protection for software and hardware.
1) Range
Adult:
Systolic pressure: 40mmHg~270mmHg
Mean pressure: 20mmHg~235mmHg
Diastolic Pressure: 10mmHg~215mmHg
Pediatric:
Systolic pressure: 40mmHg~200mmHg
Mean pressure: 20mmHg~165mmHg
Diastolic Pressure: 10mmHg~150mmHg
Neonatal:
Systolic pressure: 40mmHg~135mmHg
Mean pressure: 20mmHg~110mmHg
Diastolic Pressure: 10mmHg~100mmHg
2) Upper and lower limit of alarm
Adult:
Systolic pressure: 40mmHg~270mmHg
Mean pressure: 20mmHg~235mmHg
Diastolic Pressure: 10mmHg~215mmHg
Pediatric:
Systolic pressure: 40mmHg~200mmHg
Mean pressure: 20mmHg~165mmHg
Diastolic Pressure: 10mmHg~150mmHg
Neonatal:
Systolic pressure: 40mmHg~135mmHg
Mean pressure: 20mmHg~110mmHg
Diastolic Pressure: 10mmHg~100mmHg
SpO2 monitoring
Continuous real-time measuring.
Adopt digital SpO2 technology, which has strong anti-interference capability.
Real-time display SpO2, Pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.
Trend graph with the function of adaptive scaling
Standard finger-clip probe for adult, binding probe for neonatal is optional.
1) SpO2
MeasuringRange: 35%~100% (Resolution: 1%)
Accuracy: ± 2% in stage of 70%-100%, and unspecified in stage of less than 70%.
2) Pulse Rate
MeasuringRange: 30bpm~250bpm(Resolution: 1bpm)
Accuracy: ± 2bpm or ± 2%, whichever is greater.
3) Measurement Performance in Weak Filling Condition: SpO2 and Pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ± 4%; The Pulse rate error is ± 2bpm or ± 2%, whichever is greater. 4) Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%.
Accessories
A power adapter
An ECG lead wire
A SpO2 probe
An adult NIBP cuff
A base of the PM70
PM70 Patient Monitorcan be used for all-round monitoring for adult, pediatric and neonatal for ECG, NIBP and SpO2, etc.
Features
All-round monitoring for adult, pediatric and neonatal.
3.5'' (320× 240) TFT LCD.
Operate with button and touch screen.
Review of data list and trend graph.
Configuring interface as user's requirements.
Audible and visual alarm for each parameter, and upper and lower limit of alarm can be set.
Built-in rechargeable Li-polymer battery for uninterrupted monitoring.
Performance
ECG
3-lead and 5-lead are optional.
Waveform display: Dual-lead/full-lead
Gain selection: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV
Measurement range for Heart rate(HR): 30bpm~300bpm, error: ± 1bpm or ± 1%, whichever is greater.
Upper and lower limit for alarm range: 30bpm~300bpm, resolution: 1bpm
Input current: ≤ 0.1μ A
Enduring polarization voltage: ± 300mV, sensitivity range: ± 5%.
CMRR: Filter mode(surgery, monitoring)≥ 80dB
Frequency response: 1~75Hz(+0.4dB, -3dB)
Low-frequency characteristic: Time constant≥ 3.2s
Analysis function: Heart rate, arrhythmia analysis, S-T segment analysis
S-T segment range: -2.0mV~2.0mV
Blood Pressure
Measurement method: Oscillometry
Measurement mode: Manual/auto/continuous.
Auto measurement interval: Adjustable from 1 to 90 minutes.
Resolution: 1mmHg.
Accuracy: Maximum Mean deviation≤ ± 5mmHg, Maximum Standard deviation≤ 8mmHg.
Self-check function.
Overpressure protection: Double protection for software and hardware.
1) Range
Adult:
Systolic pressure: 40mmHg~270mmHg
Mean pressure: 20mmHg~235mmHg
Diastolic Pressure: 10mmHg~215mmHg
Pediatric:
Systolic pressure: 40mmHg~200mmHg
Mean pressure: 20mmHg~165mmHg
Diastolic Pressure: 10mmHg~150mmHg
Neonatal:
Systolic pressure: 40mmHg~135mmHg
Mean pressure: 20mmHg~110mmHg
Diastolic Pressure: 10mmHg~100mmHg
2) Upper and lower limit of alarm
Adult:
Systolic pressure: 40mmHg~270mmHg
Mean pressure: 20mmHg~235mmHg
Diastolic Pressure: 10mmHg~215mmHg
Pediatric:
Systolic pressure: 40mmHg~200mmHg
Mean pressure: 20mmHg~165mmHg
Diastolic Pressure: 10mmHg~150mmHg
Neonatal:
Systolic pressure: 40mmHg~135mmHg
Mean pressure: 20mmHg~110mmHg
Diastolic Pressure: 10mmHg~100mmHg
SpO2 monitoring
Continuous real-time measuring.
Adopt digital SpO2 technology, which has strong anti-interference capability.
Real-time display SpO2, Pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.
Trend graph with the function of adaptive scaling
Standard finger-clip probe for adult, binding probe for neonatal is optional.
1) SpO2
MeasuringRange: 35%~100% (Resolution: 1%)
Accuracy: ± 2% in stage of 70%-100%, and unspecified in stage of less than 70%.
2) Pulse Rate
MeasuringRange: 30bpm~250bpm(Resolution: 1bpm)
Accuracy: ± 2bpm or ± 2%, whichever is greater.
3) Measurement Performance in Weak Filling Condition: SpO2 and Pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ± 4%; The Pulse rate error is ± 2bpm or ± 2%, whichever is greater. 4) Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%.
Accessories
A power adapter
An ECG lead wire
A SpO2 probe
An adult NIBP cuff
A base of the PM70
| Performance Specifications | |
| Display: | 3.5" Color TFT |
| Resolution: | 320x240 |
| Display Mode: | Standard face, Waveform face |
| Indicator: | Power indicator light, Alarm sound, Pluse tone |
| Interface: | Socket for connecting sensors and sockets for communication cables |
| Power Supply: | DC 5V, < 300mA |
| Battery: | Builtin Li-Polymer, 2 hours for charging, 3 hours for continous working. 8 hours for standby mode |
| Trend Graph: | Resolution from 1s, 5s, 10s. Maximum time 96 hours. |
| Trend Table: | Resolution from 1s, 5s, 10s. Review up to 1000 items. |
| Alarm: | Ajustable High and Low limits. Three level audible and vistual alarm |
| User Configuration: | All the color of parameters and waves can be set according to user' s willing |
| Technical specifications: | |
| Safety | Meet the requirment of IEC60601 series |
| Type of Protection: | Class II with internal electirc power supply |
| Degree of Protection: | BF |
| Dimention and Weight | |
| Dimention: | 145(W)x95(H)x37(D)mm |
| Weight: | 400g(with battery) |
| Operation Environment: | Temperature: 0~ +40 |
| Humidity: 15% ~ 95% | |
| Storage Environment: | Temperature: -20~ +60 |
| Humidity: 10% ~ 95% | |
| Patient Range | Neonate, Pediatric and Adult |
| SpO2: | |
| Measurement Range: | 0 ~ 100% |
| Resolution: | 1% |
| Accuracy: | ± 2%(70%~100%, Adult/Pediatric, non-motion) |
| ± 3%(70%~100%, Neonate, non-motion) | |
| 0% ~ 69% unspecified | |
| Alarm Range: | 0% ~ 100% |
| Refreshing Rate: | 1s |
| Pulse Rate: | |
| Measurement Range: | 25 ~ 250 bpm |
| Resolution: | 1bpm |
| Accuracy: | ± 3 bpm (non-motion) |
| Alarm Range: | 25 ~ 250 BMP |
| Refreshing Rate: | 1s |
| NIBP: | |
| Method: | Oscillometry |
| Mode: | Manual/Auto/Contiuous |
| Measurement Range: | 25 ~ 260mmHg |
| Atuo Measure Interval: | 5, 10, 15, 30, 45, 60, 90 Minutes |
| Resolution: | 1mmHg |
| Overpressure Protection: | 300mmHg |
| Alarm range: | 25 ~260mmHg |